Expert calibration lab in
Manaus – Brazil
Opening hours
Portaria 4, Bloco J, Setor B
Distrito Industrial I
CEP 69075-351
Manaus/AM

ACCREDITATIONS
CAPABILITIES
Electricity
Global Calibration Scope
- AC Power & Energy: Triphasic active & Active Monophasic f = 50 – 60 Hz, 0,7 W ≤ P ≤ 71 MW, (Wattmeters, Energy analyzers, Power analyzers, Watt-hour meters, Power converters, multifunction calibrators, Sources for meter or relay testing
- High voltage:
- DC: 1 kV to 200 kV
- AC (50 Hz): 1 kV to 175 kV
- Magnetometers: 0 to 1700 mT…
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Humidity
Global Calibration Scope
- Dew Point sensors ranging -90° C to +95° C
- RH from 0% – 100%
Common equipment serviced: Dew point sensors, Dew point transmitters, Dew point meters and probes, Hygrometers, Humidity indicators, Moisture meters, Humidity sensors, Humidity loggers, Thermohygrograph, Psychrometers, RH indicators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Pressure / Vacuum
Global Calibration Scope
- Vacuum: primary and secondary
- Altimeter: up to 47 000 m
- Pressure gauge: up to 500 MPa
Common equipment serviced: Manometers, Pressure calibrators, Sensor transmitters, Vacuum, Safety devices, Pressure balance
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Temperature
Global Calibration Scope
- Range: -196°C up to 1550°C
- Fixed points: TP Ar, TP Mercury, TP Water, Melting point of Galium, FP Indium, FP Tin, FP Zinc, FP Al, FP Ag…
Common equipment serviced: temperature measurers, Generators/calibrators, Chillers, Thermistors, Infrared radiation sources, Temperature Controllers, Temperature Indicators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Time / Frequency
Global Calibration Scope
- Tachometer, stroboscope: 1 up to 600 000 RPM
- Frequency meters, frequency generators, counters: up to 40 GHz
Common equipment serviced: Digital Timers, Frequency Counters, Frequency Meters / Generators, Frequency Standards, Stopwatches, Stroboscopes, Tachometers, Timers, Phasemeter, Standard RPM generators, Synchro-resolvers, Signal generators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Volume
Global Calibration Scope
- Volumetric Instruments (Beakers, Volumetric Containers…): up to 20 000 mL
- Pipette: 0.1µL up to 1 000 mL
- Syringe: up to 200 mL
Common equipment serviced: Burettes, Flask, Syringe, Pipettes, Test tubes, Beakers, Dispenser, Tanks, Vessels, Gauge overflow, Gauge windows, Concrete air content meters, Level probes Pycnometers, Titrators
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Air Velocity
Scales
Global Scope:
- Non-automatic weighing instruments (NAWI) with maximum capacity up to 240 tons (legal metrology, maintenance and repair)
- Automatic weighing instruments (AWI) with maximum capacity up to 2000 kg
Common equipment serviced: NAWI, AWI (hopper weighing scales, gravimetric filling instruments, catch weighing scales, dynamic railway weighing, dynamic vehicle weighing, etc.)
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.
Sphygmomanometer legal metrology
Global Scope:
- Leak 0 ≤ F ≤ 200mmHg/min
- Non-Invasive Blood Pressure 0 ≤ P ≤ 400mmHg
- Heart Rate 20 ≤ F ≤ 300Bat/min
- Fast Air Exhaustion 1 ≤ E ≤ 999 s
Common equipment serviced: Sphygmomanometers
This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.